Product Details:
Payment & Shipping Terms:
|
Type: | Power Relay | Rated Voltage [V: | 24VDC |
---|---|---|---|
Rated Current: | 60A | Coil Voltage: | DC6-220V AC6-380V |
Mounting: | Bolt Rail Mounting | Working Life: | 100000 |
Temperature: | -30~80 | Operate Time: | 50MS |
Rated Power: | DC2W AC 6VA | Size: | 67*67*60.5mm |
Contact Form: | 1Z 1H 1D | ||
High Light: | jqx 60f automotive power relay,12v dc automotive power relay,220v 60 amp automotive relay |
1.JQX 60F 1Z 60A 12V DC 24V DC 220V AC Coil Power Relay
2.Product feature
1. Shock Resistance Strong, seismic resistance, Long Working Life
2. Provides 1 set of contact conversion
3. Load, switch Power: 60A
4. Bolt type, Rail mounting
3.Contact Form Description
Changeover Type (Z):
In the middle there is a moving contact, when the coil is not energized, the moving contacts will be disconnect and one of the static contacts will be closed. After the coil is energized, the moving contact will move, makes the original broken change to closed state, and original closed state changed to disconnected state, to achieve the purpose of conversion.
Normally Open Type (H):
The contact is disconnect state when coil is not energized, and contact will be closed when coil is energized.
Normally Closed Type (D):
The contact is closed state when coil is not energized, and contact will be disconnected when coil is energized.
Contact Parameters
Contact Form | 1Z, 1H, 1D |
Contact Load | 60A |
Max Switching Voltage | 240VAC 60A, 28VDC 60A |
Contact Material | Silver Alloy |
Operation Coil
Rated Voltage | DC12V | DC24V | DC110V | DC220V |
Rated Current mA | 167 | 83.3 | 18.2 | 9 |
Coil Resistance Ω | 71.8 | 288 | 6044 | 24444 |
Rated Power dissipation W | 2.0W | |||
Pull In Voltage Max V | Under 75% | |||
Release Voltage Min V | Over 10% | |||
Tolerate Voltage Max V | Rated Voltage x 110% |
Rated Voltage | AC12V | AC24V | AC110V | AC220V |
Rated Current mA | 716.7 | 358 | 78.2 | 39 |
Coil Resistance Ω | 5.9 | 23.4 | 492 | 1974 |
Rated Power dissipation W | 8.6VA | |||
Pull In Voltage Max V | Under 80% | |||
Release Voltage Min V | Over 30% | |||
Tolerate Voltage Max V | Rated Voltage x 110% |
4.Product Parameter
Contact Resistance | < mΩ | |
Electrical Life | > 105(Frequency 1s connect, 1s Break) | |
Mechanical Life | >107 (Frequency 300times/minute) | |
Coil Voltage | DC: 6-220V AC:6-380 | |
Pull in Time | < 25ms | |
Release Time | <15ms | |
|
Between Homopolar Contact | 1500VAC/1min |
Between Heperopole Contact | / | |
Between Contact and Coild | 2500VAC/1min | |
Insulate Resistance | > 200MΩ (500VDC) | |
Environmental Temperature | -55℃ ~+ 70℃ | |
Environmental Humidity | 35% ~ 80% RH | |
Air Pressure | 86~ 106KPa | |
Shock Resistance | 10G (Sine Wave Half Pulse 11ms) | |
Vibration Resistance | 10-55HZ Double Amplitude: 1.5mm | |
Size | 63.2x 46 x46 mm | |
Weight | About 160g |
5.Selection Guide
For relays that are not clearly stated, all load currents marked on the Huiyou relay housing are resistive loads. Under the rated switching voltage, the allowable current of the inductive load should not exceed 30% of the rated resistive load, and the allowable motor load The current should not exceed 20% of the rated resistive load, the allowable current of the lamp load should not exceed 10% of the rated resistive load, and the allowable current of the capacitive load should not exceed 5% of the rated resistive load. For the actual use of the product For reliability, it is recommended to select the contact load current value not to exceed 60%-70% of the stable current value under the rated load of the product when selecting the model.
6.Attention
Do not touch the relay terminal part and the connected electrical accessories when the power is on, and perform the installation and maintenance of the relay.Please cut off the power when troubleshooting.
Do not use the relay beyond the rated load. Overload use may cause insulation performance degradation, contact sticking, contact unequal failure, and even damage to the relay itself.
Please avoid dropping the product during storage and use, and do not disassemble the internal components, which may cause damage, burnout and electric shock on one side.
Do not use in spontaneous combustion, explosive gas and other environments. And avoid using it in places where there is water, steam, melting after freezing, or where water droplets fall.
The relay coil has polarity. When connecting the terminals, please refer to the wiring diagram and then perform the correct wiring.
Avoid continuously applying voltage to the coil that exceeds the maximum switching voltage.
7. Guarantee
To make you rest assured about the after-sale,we would like to provide one-year quality guarantee.
8. Sample Policy
To enhance more understanding of each other and our products,we’d like to provide the sample free to you for testing.
9. Terms of payment
T/T 30% as deposit, and 70% before delivery. We'll show you the photos of the products and packages before you pay the balance.
10. Delivery time
Generally, it will take 20 to 45 work days after receiving your advance payment. The specific delivery time depends on the items and the quantity of your order.
We are the manufacturer of auto parts for more than 10 years, definitely we can provide you with good quality, good price and good service.
Contact Person: Miss. Tracy
Tel: 18395806194
Fax: 86-0574-88044539